Fora coils use kit part no.
Fan coil unit installation guide.
This allows for modular unitstobedisassembledandcomponentsmovedseparately to installation area for reassembly.
Allow space for wiring piping and servicing unit.
Remove blower and coil access panel and fitting panel refer to figure 6.
The fan coil should be connected with the cooling or heating medium pipe after the duct system is purged in case of the heat exchanger being blocked.
For slopefan coils use kit part no.
Only use the accessories provided by daikin to install the option.
P series t701dfp installation guide operating manual.
The ekrp1c11 can only be used to connect the valves.
N series f series and v series tec3000 color screen product bulletin catalog sales flyer.
Unit installation measure and mark the position for the hanging rod.
Use fireproof resilient gasket 1 8 to 1 4 in 3 to 6 mm thick between duct unit and floor.
Fix the standard unit to the ceiling or wall using at least 4 of the 6 slots.
Installation instructions fan coils.
Preface krueger fan coils represent a prudent investment which can with proper installation operation and regular maintenance give trouble free operation and long service.
The installation template is extended according to temperature and humidity.
Check on dimensions in use.
Your equipment is initially protected under the.
Drill the hole for the angle nut on the ceiling and fix the hanging rod.
Fem4x fem4p rem4x fxm4x 6 specifications are subject to change without notice.
Installation instructions supplied with kit for proper installation.
Connection of first valve.
Hl series c horizontal low profile fan coil unit.
Note to ensure proper drainage for horizontal installations unit must be installed so it is within 1 8 in.
The dimensions of the installation template are the same as those of the.
N for horizontal installation ceiling mounting it is advisable to use m8 thre aded bars screw anchors suitable for the unit s weight and to arrange for the positioning of the unit using 2 m8 bolts and a washer the diameter of which is suitable for inserting the slot and for then fixing the unit.
Unit installation about fan coil installation please refer to the dimensional drawings and installation diagram.
Install or service any unit without following safe practices regarding mechanical equipment.
Do not drill any holes in the casing of the unit to install the option.
Figure 2 upflow installation.
Level of the length and width of unit.
1 communication to fan coil pcb 2 power supply wire to fan coil unit 3 fuses 5 a 250 v 4 yc y1.
Fem4x6000b rem4x6000b and fxm4x4800 6000 fan coils are two piece modular units.
Installation guide operating manual.
Procedure 2 mount fan coil unit can stand or lie on floor or hang from ceiling or wall.
This process accommodates small scuttle holes and limiting entrances to installation sites figure 1.
Gasket kit number kfahd0101slp is also required for.
Hl series d horizontal low profile fan coil unit.